Guardian Series™ Variable Frequency Controllers
Guardian Series™ Variable Frequency Controllers
Variable speed pumping systems, powered by Guardian Series™ Variable Frequency Controllers, ramp up the system's horsepower as needed to provide optimal flow rates at fueling points. The result is faster and more consistent flow rates at peak business times compared to fixed speed systems.
By incorporating features such as precise flow control, fault diagnostics, and protective mechanisms, the Variable Frequency Controller enhances operational performance, reduces maintenance costs, and extends equipment lifespan.
Since bringing variable speed pumping to the service station industry in 1996, Franklin Electric has provided customers with consistent fueling experiences and improved uptime.
Automatically adjusts pump speed for optimal flow rates
Maintains faster flow rates during peak business
Provides consistent customer fueling experience
Maintains stable performance with fluctuating demand
Minimizes pressure spikes preventing system wear
Helps maximize profits with higher flow rates
System diagnostics maximize uptime
Advanced control via EVO™ Series Turbine Pump Interface™
The Guardian Series™ Variable Frequency Pump Controller brings advanced performance and efficiency to fueling operations. Designed to optimize flow rates, this intelligent controller adjusts pump motor speeds in real time to maintain consistent fuel flow, even during peak demand.
Guardian Series™ Variable Frequency Controllers redefine the standard of variable speed pump control. Built on the trusted FE PETRO® intelligent controllers, Guardian Series™ controllers deliver an improved user interface, streamlined design, and superior performance compared to any other pumping systems in the marketplace.
Clear Digital Display
3½ digit LCD shows running / fault status & last five faults for easier troubleshooting.
Improved Cooling
Centralized heat sink / fan and temperature monitoring improve reliability in challenging applications.
Boosted Performance
Supports 4 Hp pumps with increased performance of about an additional nozzle versus legacy MagVFC™.
Advanced Pump Protection
Improved over voltage protection and underload detection safeguard equipment.
Improved Diagnostics
Displays more in-depth fault readouts, motor phase issues, and last five faults for enhanced troubleshooting.
Reduced Electrical Noise
Enhanced output filter reduces output noise to lowest levels.
Enhanced Surge Protection
Upgraded incoming power circuit reliably handles more challenging power conditions.
Superior Cooling
Improved thermal design allows for reliable performance in extended operating conditions.
LCD Display
A 3½ digit LCD display provides readable running and fault status for improved troubleshooting.
Output Conditions
Readable output conditions are listed on the front panel for quick reference.
Dual Buttons
Separate Reset and Silence push buttons provide easy interaction with the controller.
Communication LED
A yellow LED provides a visual confirmation of communication between the controllers.
Since hitting the market in 1988, FE PETRO® Submersible Turbine Pumps (STPs) have developed a reputation as the standard in performance, quality and dependability with innovative features only available from Franklin Electric. It is, and always will be about filling cars faster and smarter.
2 Hp & 4 Hp variable speed pump options
Biofuel compatibility handles ethanol / biodiesel blends
Advanced protection prevents corrosion / extends life
MagShell® increases flow area around motor for higher flow
Variable length adjustment ensures perfect onsite fit
Active air elimination for smooth fuel delivery
Safe and simple service disconnects and pressure relief
Intake filter screen keeps debris out / reduces wear
Turbine Pump Interface (TPI) is a powerful tool that creates a network between intelligent pump controllers and EVO™ Series fuel management system consoles.
Turbine Pump Interface
Through TPI, the EVO™ has access to the submersible pumping system status and the capability to react with intelligence that pump controllers alone cannot. The devices share data to provide enhanced system capabilities.
Detect and automatically react to offline systems
Faster pump reset and avoided downtime
Enable remote troubleshooting
Prevent maintenance calls and trip charges
Prevent fuel runouts, dry runs, and tank overfills
Power Requirements
| 2 Hp submersible pumps | Single-phase incoming power |
| 2 Hp & 4 Hp submersible pumps | Three-phase incoming power |
| Incoming power supply | 200-250 VAC |
| Output | Three-phase, variable frequency signal* |
| 2 Hp max. motor draw | 9 Amps |
| 4 Hp max. motor draw | 15 Amps |
| Single phase input max. current | 9.5 Amps |
| Three phase input, VS2 max. current | 11.5 Amps |
| Three phase input, VS4 max. current | 16 Amps |
| Max. line draw | 20 Amps |
| Single phase input max. current | 19 Amps |
| Three phase input max. current | 18 Amps |
- *For use with FE PETRO® variable speed pumps only.
Environmental
| Dimensions | 15.61" H x 5.3" W x 10.1" D |
| Minimum mounting clearance envelope | 24.6" H x 14.3" W |
| Weight | 20.2 lbs. |
| Location | Non-hazardous environment, indoors where explosive or flammable vapors are not present |
| Altitude | Up to 2,000 m |
| Temperature | 40° F to 122° C (4° C to 50° C) |
| Humidity | 0–95%, non-condensing |
| Overvoltage | UL 61800-5-1 CATEGORY III |
| Pollution | UL 61800-5-1 DEGREE 2 |
| Enclosure type rating | UL Type 1 |
| Approvals / certifications | UL / ULc listed, ISO 9001:2015 certified manufacturer |
Ratings
| Single phase input rating | 200 - 250 VAC, 50/60 Hz, 19 A, 1-phase |
| Three phase input rating | 200 - 250 VAC, 50/60 Hz, 18 A, 3-phase |
| Single phase output rating | 190 VAC, 70 Hz, 9.5 FLA, 3-phase |
| Three phase output rating | 190 VAC, 70 Hz, 16 FLA, 3-phase |
| Switch hook | 120 - 240 VAC, 50 / 60 Hz, 16 mA |
| Supply / motor wiring | 10 - 12 AWG (2.5 - 6.0 mm²), 90° C, 300 V minimum |
| Supply hook wiring | 10 - 18 AWG (0.75 - 6.0 mm²), 90° C, 300 V minimum |
Communication
| User interface display | 7 segment, 31/2-digit LED screen |
| Activity indicator light | Yellow RS485 LED light |
| Communication terminal | RS485 |
| Service port | USB for temporary use by service personnel only |
Guardian Series™ Variable Frequency Controllers
1. User interface display
2. Alarm silence button
3. Controller reset button
4. RS485 activity indicator LED
5. Fault codes
6. Rotary select switch
7. SW3 option select switch
8. SW2 option select switch
9. SW1 option select switch
10. RS485 comm. terminals
11. Frequency limit switch
12. Motor output terminal
13. Incoming power terminal
14. Incoming dispenser hook
15. USB service port
16. Cooling fan
2 Hp Variable Speed Pump Performance Chart
4 Hp Variable Speed Pump Performance Chart
Guardian Series™ Variable Frequency Controller
| Model Number | Description |
|---|---|
| 5874202220 | Guardian Series™ Variable Frequency Controller, 60 Hz, 220 V |
Featured
Brochures
| Title | Type | Size | |
|---|---|---|---|
| FFS-1049 Variable Speed Pumping Systems Brochure.pdf | 11.1 MB | ||
| FFS-1050 Guardian Series Variable Frequency Controller Datasheet.pdf | 1.06 MB | ||
| FFS-1051 VFC Comparison Brochure.pdf | 0.68 MB | ||
| FFS-1062 Guardian Series Variable Frequncy Controller Technical Quick Reference.pdf | 1.08 MB | ||
| FFS-1017 Submersible Pumping Systems Brochure.pdf | 14.92 MB |
Catalogs
| Title | Type | Size | |
|---|---|---|---|
| FFS-1028 2025 UL Ordering Catalog.pdf | 95.03 MB | ||
| FFS-0807 (EN) Product Catalogue.pdf | 153.77 MB | ||
| FFS-0367 (UL) Site Starters Ordering Guide.pdf | 64.42 MB |
Manuals
| Title | Type | Size | |
|---|---|---|---|
| 10000009501 VFGC 220 Installation Guide.pdf | 2.11 MB |